| Home | Corporate Info | Certification | Infrastructure | Industries | Events | Downloads | Contacts | Query |
![]() |
Instrumentation Applications » Bleed
Valves: Series - BLV |
||
Features» Available in SS316 » Compact and convenient installation » Vent tube design prevents accidental removal of the stem » Vent tube directs excess liquid or gas from system line » Variety of end configurations includes Male NPT, BSPT and SAE pipe connections » Flow coefficient (Cv) 0.25 » Orifice size 0.125" (3.20mm) » Every valve is factory tested Applications » General Plant Service » Instrument isolation » Hydraulic and Pneumatic » Pressure measurement devices » Venting Operating Parameters Pressure Rating : Upto 10000 psig (689 bar) at CWP Temperature Rating : -54 °C to 454°C ![]()
Testing Standard Test : Each valve is factory tested with nitrogen at 1000 psig (69 bar) for leakage at the seat, the maximum allowable leak rate of 0.1 sccm Optional Hydrostatic Test : This test is performed with de-ionised water at 1.5 time the ![]()
|
|||||||||||||||||||