Choose Language
Single Ferrule Compression Tube FittingsSingle Ferrule Compression Tube Fittings

Single/Twin Ferrule Compression Tube Fittings (Fine-LokTM / Well-LokTM) - General Information


INSTALLATION INSTRUCTIONS

Fine-LokSealexcel India Pvt.Ltd./Well-LokSealexcel India Pvt.Ltd. Tube Fittings
  1. Ensure that, the end of the tube is cut square and free from burrs without causing undue chamfering of the tube end.
  2. Loosen the fitting Nut.
  3. Insert the tubing into the fitting assembly resting it firmly on the internal shoulder of the fittings.
  4. Finger tighten the nut.
  5. A) Tighten the nut with a wrench 1 ¼ turns from the finger tight position. For the tube fittings size 6mm / 1/4" and above.

    Sealexcel India Pvt.Ltd.

    B) Tighten the nut with a wrench 3/4" turn from the finger tight position for the tube fittings size 4mm / 3/16” and below.

    Sealexcel India Pvt.Ltd.

Seal Excel

SEALEXCELSealexcel India Pvt.Ltd. RECOMMENDATION

For high pressure application
Due to variation in the tubing diameter SEALEXCELSealexcel India Pvt.Ltd. recommends the following instructions for safety and excellent performance of high pressure applications.

  1. After insertion of tubing to the fittings assembly, tighten the nut approximately 1/8 turn with a wrench from finger type position or until the tubing does not rotate freely by hand.
  2. Further tighten the nut with a wrench 1 ¼ turns to have a firm and safe grip.

Seal Excel

REASSEMBLY INSTRUCTION

SEALEXCELSealexcel India Pvt.Ltd. Tube fittings may be assembled and disassembled repeatedly. The following instructions should be carried out to reassemble the fittings..

  1. Firmly insert the tubing end with the previously set ferrules into the fitting body and tighten the nut to a hand-tight condition.
  2. With a wrench, tighten the nut until a sharp condition rise in torque is felt, then simply snug with wrench.

Seal Excel

SAE / MS STRAIGHT THREAD AND ISO PARALLEL THREAD POSITIONABLE:-

Elbows and Tees Installation procedure:

Sealexcel India Pvt.Ltd.


  1. Lubricate the ‘O’ -ring with lubricant compatible with the system fluid and ‘O”-ring material.
  2. Turn the fittings into the straight thread port until the metal back-up washer contacts the face of the port.
  3. Position the fittings by backing it out, (not more than one turn).
  4. Hold the fittings in position and tighten the lock nut until the washer contacts the face of the port.

NOTE:
  1. SAE/MS positionable elbows and tees are compatible with SAE J1926 ports.
  2. ISO parallel thread positionable elbows and tees are compatible with female ports having BS 2779 threads.

Face Seal ‘O’-Ring Fittings:
Installation Procedure:

The ‘O’- ring requires a smooth, flat seating surface, this surface must be perpendicular to the axis of the threads.
  1. Turn the ‘O’- ring seal fitting in the port until finger tight.
  2. The squeezing effect on the 'O'- ring can be felt during the last ¼ turn.

Seal Excel

SAE SPECIFICATION

SEALEXCELSealexcel India Pvt.Ltd. SAE Straight thread ‘O’-ring fittings are designed and manufactured to meet SAE standard as follows-
  1. Male or External fittings End (Dimension: SAE J514)
  2. Straight thread SAE J475 (Equivalent to ANSI B1.1 or ISO R725)
  3. Female or Internal Straight thread (Port : SAE J1926)

SEALEXCELSealexcel India Pvt.Ltd. Tube fittings with SAE Ends Straight thread

SAE Straight Thread ‘O’-Ring seal fittings are designed and manufactured to SAE standards defined below for use in many different application including hydraulics and natural gas vehicles.
SAE Straight thread fittings are supplied with viton ‘O’-rings.

FITTINGS AVAILABLE INCLUDES
Connectors, Positionable SAE Elbows and Tees and SAE reducers.
Thread and ‘O’ring Sizes:-

Nominal Tube
OD.
Port Size Thread Size ‘O”-ring
Size no.
1/8
1/4
3/8
1/2
5/8
3/4
1
125
250
375
500
625
750
1000
5/16-24
7/16-20
9/16-18
3/4-16
7/8-14
1 1/6-12
1 5/16-12
902
904
906
908
910
912
916

Seal Excel

PORT CONNECTOR INSTALLATION PROCEDURE

  1. Remove nut and ferrules from the first of two Fine-LokSealexcel India Pvt.Ltd. / Well-LokSealexcel India Pvt.Ltd. ports to be connected.
  2. Slip nut only on port connector over machined ferrule.
  3. Insert connector into first port and snug up nut by hand. Tighten the nut with wrench ¼ turn only.
    For 1/8, 3/16, 3mm and 4mm tube fittings, tighten the nut 1/8 turn from finger tight position, subsequently connections are made snugging the nut by hand.
  4. Insert other end of port connector into Fine-LokSealexcel India Pvt.Ltd./Well-LokSealexcel India Pvt.Ltd. port 2, and tighten the nut 1 ¼.
    For 1/8, 3/16, 3mm and 4mm tube fittings tighten the nut ¾ turn from finger tight position.



Seal Excel

PLUG INSTALLATION PROCEDURE

For 6mm, ¼ and above size Tube Fittings, tighten the plug with wrench ¼ turn from finger tight position.
For 1/8, 3/16, 3mm and 4mm tube fittings, tighten the plug with wrench 1/8 turn only..

Make subsequent connection by tightening slightly with wrench after snugging the nut by hand.


Seal Excel