INSTALLATION INSTRUCTIONS
Fine-Lok
- Ensure that, the end of the tube is cut square and free from burrs without causing undue chamfering of the tube end.
- Loosen the fitting Nut.
- Insert the tubing into the fitting assembly resting it firmly on the internal shoulder of the fittings.
- Finger tighten the nut.
- A) Tighten the nut with a wrench 1 ¼ turns from the finger tight
position. For the tube fittings size 6mm / 1/4" and above.

B) Tighten the nut with a wrench 3/4" turn from the finger tight position for the tube fittings size 4mm / 3/16 and below.